AC charger for electric vehicles
Read all instructions before installation and operation
1.1 Warnings and alerts
| Residual current relay | Single-phase | Three-phase 16A | Three-phase 32A |
|---|---|---|---|
| Output current (A) | 32A | 16A | 32A |
| Residual current relay (A) | 40A | 20A | 40A |
1.2 Installation requirements
1.3 Routine maintenance
2.1 Basic interface
The charger includes: a digital display, mounting holes (top and bottom), a charging cable outlet, a LAN cable inlet, and an AC power input cable.
2.2 Basic dimensions
Enclosure dimensions: 190 mm (width) × 330 mm (height) × 87 mm (depth). Mounting hole spacing: 215 mm.
2.3 Technical specifications
Technical data
| Model number | DSG-6012 |
| Rated input voltage | 230Vac ±10% / 400Vac ±10% |
| Rated output current | 7kW/32A / 11kW/16A / 22kW/32A |
| Standards compliance | IEC 61851-1, IEC 61851-21-2 |
| Charging connector | Fixed 5 m IEC Type 2 cable |
| Charging mode | Mode 3 |
| Electrical protections | UVP, OVP, RCD (DC 6mA), SPD, OCP, OTP |
| Energy meter | Built-in meter, ±1% accuracy |
Features and network
| User interface | Digital display |
| Cable entries | Bottom side, multiple |
| Connectivity | LAN Ethernet, BT, Wi-Fi |
Environment
| Operating temperature | -30°C to 50°C |
| Operating humidity | Up to 95% RH, non-condensing |
| Protection rating | IP54 |
Physical
| Enclosure material | UV-treated PC |
| Dimensions (mm) | 330 × 190 × 87 (height × width × depth) |
| Net weight | About 8 kg |
Additional options
| Charging connector | Fixed 5 m IEC Type 2 cable |
| Communication protocol | OCPP 1.6J |
| Emergency stop button | with protective cover |
| Data connection | Server-side service via OCPP / home app |
| NFC authentication | ISO/IEC 14443A / MIFARE (13.56 MHz) |
| Mounting pedestal | Single / back-to-back mounting |
Check that the package contains the following parts:
| No. | Product name | Quantity | Description |
|---|---|---|---|
| 1 | AC charger | 1 | with the input power cable and output charging cable connected |
| 2 | User manual | 1 | A PDF version is available on the company website dsgcs.co.il |
| 3 | Screws | 2 | For mounting the AC charger on the wall/structure |
| 4 | Wall plug | 2 | For securing the screw to the wall/structure |
| 5 | Screw cover | 1 | To cover the screw |
| 6 | Standard RFID cards | 2 | To start/stop the charger |
| 7 | Mounting template | 1 | For easy drilling of 2 screw holes |
Required tools: before mounting the charger on the wall, prepare the following tools:
- Wire stripper
- Adjustable wrench
- A voltage tester or digital multimeter (to measure AC voltage at the installation site)
- Level
- Pencil or marker
- Drill
- Phillips screwdriver
Choose a suitable mounting location with electrical capacity:
I. Make sure the chosen mounting location allows the charging cable to reach the car's charging port with some slack.
II. The device must be anchored to a solid wall or frame measuring: 80 mm × 130 mm.
III. The device should be installed 1.2 m above the ground.
Drill 2 screw holes 12 mm in diameter and 57 mm deep using mounting template no. 7. Drill the screw holes in the direction of the arrow on the template.
Insert the 2 wall plugs (no. 4) into the holes and screw in the top screw (no. 3). The distance between the screw head and the wall is about 5 mm.
Align the charger's rear slot with the holes and hang the top slot on the top screw, then insert the screw (no. 3) into the bottom hole.
Cover the screw with the screw cover (No. 5).
Attach the inner cover to the charger with two screws and tighten the outer cover.
General view after installation.
For safety, install an RCD on the input side of the EV charger.
Single-phase connection
Connect the L1 conductor to the mains L1, connect the N conductor to the mains N, connect the PE conductor to the mains PE.
| Single-phase | |
|---|---|
| Output current | 32A |
| Residual current relay | 40A |
Three-phase connection
Connect the L1 conductor to L1, L2 conductor to L2, L3 conductor to L3 of the mains, N conductor to N and PE conductor to the mains PE.
| 16A | 32A | |
|---|---|---|
| Output current | 16A | 32A |
| Residual current relay | 20A | 40A |
8.1 Operating steps with Plug and Charge
After switching on the power, you'll see "Please Plug In" on the device screen.
Connect the charging connector to the car's charging port.
While charging, you'll see on the screen: "Charging", voltage, current and kWh.
If a warning sign ⚠ appears, try reconnecting the vehicle connector. If the sign keeps appearing, see section 9.2.
When charging is complete, the total kWh will be displayed. Disconnect the charging connector.
8.2 Operating steps with RFID
After switching on the power, you'll see "Please Plug In" and "Scan QR Code or Tag Card".
Connect the charging connector to the car's charging port.
Connect the charging connector to the car's charging port and hold the RFID card against the designated spot.
While charging, you'll see on the screen: "Charging", voltage, current and kWh.
When you swipe the RFID card to stop charging, the total kWh will be displayed. Disconnect the charging connector.
9.1 Display details
The screen shows: charging message, charging status, plug-in request, signal strength, network connection, scheduled charging, costs, voltage (V), current (A), energy (kWh), scan QR code or tag card, and Bluetooth.
9.2 Error and warning messages
| Status | Display | Note |
|---|---|---|
| Earth disconnection | 0001 | Automatic recovery |
| RCD fault | 0002 | Automatic recovery |
| Overcurrent protection | 0004 | Automatic recovery |
| Surge protection | 0008 | Automatic recovery |
| Undervoltage protection | 0016 | Automatic recovery |
| Energy meter fault | 0032 | Contact customer service |
| Control Pilot fault | 0128 | Automatic recovery |
| Overheating protection | 0256 | Automatic recovery |
| Earth fault | 0512 | Automatic recovery |
| Earth self-test | 1024 | Automatic recovery |
- The product warranty is 24 months from the date of purchase (hereinafter: "the Warranty Period") and is subject to presentation of a purchase invoice.
- The customer undertakes to notify the Company immediately of any fault, defect or damage (hereinafter: "the Fault") caused to the product, as soon as the Fault occurs, and not to use the product until the Company has finished handling the Fault.
- The product warranty is limited to repair or replacement of a part, insofar as the Company's technician finds that the part is faulty or defective and the defect is a manufacturing defect only. All parts replaced during the Warranty Period are covered by the original Warranty Period, and their replacement does not extend the Warranty Period.
- The Company may update the charging station's operating software automatically or physically at its discretion from time to time.
- The Company may act to repair the Fault at its discretion, whether by remote repair or by a technician on site or in the lab.
- The date and hours of a technician visit on behalf of the Company will be coordinated with the customer according to the Company's business hours and in accordance with any law.
- If the fault in the product is covered by this warranty form, the product will be repaired free of charge.
- If special work outside the scope of the warranty is required, it will involve an additional payment.
- During the Warranty Period, repair of a fault or receipt of a replacement station will be as set out in the Consumer Protection Regulations (Warranty and After-Sales Service), 5766-2006, as in force on the product delivery date, and stand, as of the publication of this warranty, at 7 days from receipt of notice of the fault.
- If the technician decides that the charging station cannot be repaired, the Company may, at its sole discretion, replace the station with another station with similar features and in the same condition.
- It is clarified that if the customer does not cooperate with the Company in resolving a fault that requires a technician visit, the visit will be charged at ₪590.
- The warranty is limited to the product at the address registered as the installation address. If the product has been moved from the registered address, the warranty will not apply, unless the Company's prior written approval was given and a removal and installation confirmation by a certified electrician was presented to the Company, and no damage was caused to the product during its removal and reinstallation.
- The warranty will not apply in the following cases:
- Damage and faults resulting from improper use of the product, improper installation and unsuitable electrical voltage, including disturbances in the electricity network that caused damage to the product.
- Damage caused by force majeure, including lightning, floods, natural disasters, war, hostile acts, etc.
- Malicious acts or negligence, including breakage, accident, vandalism, destruction or use of the product contrary to the instructions for connecting the product to the electrical infrastructure, the operating, maintenance and safety instructions, or contrary to any law.
- An outside party that handled the product instead of the company.
- If the Company finds that the fault resulted from one of the causes listed in section 13 above, the Company may charge ₪590 for the visit to the customer's home, in addition to the cost of repairing the fault according to the price quote sent to and approved by the customer, and/or remove the entire warranty from the product.
- Before a technician visit, and to ensure the customer's compliance with the undertaking set out in section 14 above, the customer will sign an undertaking form and provide credit card details as security.
- If the product was purchased from the Company and installed by an electrician on the customer's behalf, the warranty will not be valid if the installation was not carried out in accordance with the Electricity Law. To prove the installation, the customer will present an installation confirmation from a certified electrician.
- If the installation was carried out by an electrician on behalf of the Company, responsibility for the installation lies with the electrician whose details were given to the customer.